Print Back
Uses: Designed for those who desire a hardening furnace, a quench tank plus a separate furnace for tempering or drawing all within a Minimum floor space. The two chambers allow for immediate tempering or drawing after quench without waiting for the hardening furnace to cool to the lower temperature required.

Controls: Both chambers are equipped with their own electronic control, thermocouples and solid state relays. Auto tuning microprocessor based controls are accurate to ± 1/4 of 1%. Each

more
Unit of Measure

Specifications

Upper Chamber Width

12 in

Upper Chamber Length

40 in

Upper Chamber Height

8 in

Lower Chamber Width

12 in

Lower Chamber Length

37 in

Lower Chamber Height

8 in

Overall Width

36 in

Overall Length

58 in

Overall Height

56 in

Max. Temperature Upper Chamber

2250 ºF

Max. Temperature Lower Chamber

1250 ºF

Input Power

516 kW

Weight

1400 lb

Options

3 phase 480 volts Audible buzzer High limit controls Inlet port for protective inert Atmosphere