Print Back
Uses: Designed for those who desire a large hardening furnace plus a separate furnace for tempering or drawing, all within a Minimum floor space. The two chambers allow for immediate tempering or drawing after quench without waiting for the hardening furnace to cool to the lower temperature required.

Controls: These furnaces come standard with two sets of individual digital programmable control and a digital high limit safety control. Solid state power switching to the heating elements. Each

more
Unit of Measure

Specifications

Upper Chamber Width

15 in

Upper Chamber Length

20 in

Upper Chamber Height

15 in

Lower Chamber Width

15 in

Lower Chamber Length

15 in

Lower Chamber Height

15 in

Overall Width

33 in

Overall Length

46 in

Overall Height

67 in

Max. Temperature Upper Chamber

2250 ºF

Max. Temperature Lower Chamber

1250 ºF

Input Power

18 kW

Weight

2000 lb

Optional Voltage

208 480

Options

2000°F lower chamber Both doors side opening Quench tanks Stainless steel port